Switch Policy Status
Objects
Measures
Measure Description
Possible Actions
Chassis
BAD_PWR — Absent or faulty power supply
Power supply thresholds detect absent or failed power supplies, and power supplies that are not in the correct slot for redundancy.
Status Critical
Status Marginal
FICON Management Service
BAD_TEMP — Temperature sensors outside range
Temperature thresholds, faulty temperature sensors.
BAD_FAN — Absent or faulty fans
Fan thresholds, faulty fans.
FLASH_USAGE2 — Flash usage
Flash thresholds.
WWN_DOWN — WWN faulty or down
Faulty WWN card (applies to modular switches).
DOWN_Core — Core blade monitoring
Faulty core blades.
FAULTY_BLADE — Faulty blades
Faulty blades (applies to modular switches).
HA_SYNC — HA monitoring
High availability (HA) state of the active CP is out of synchronization with the HA state of the standby CP.
Local Switch
MARG_PORTS — Percentage of marginal ports
Physical port, E_Port, FOP_port (optical), and FCU_Port (copper) port thresholds. Whenever these thresholds are persistently high, the port is Marginal.
Status Critical
Status Marginal
FICON Management Service
FAULTY_PORTS — Percentage of faulty ports
Hardware-related port faults.
MISSING_SFP — Percentage of missing SFP transceivers
Ports that are missing SFP transceiver.
ERR_PORTS — Percentage of error ports
Ports with errors.