Objects | Measures | Measure Description | Possible Actions |
|---|---|---|---|
Chassis | BAD_PWR — Absent or faulty power supply | Power supply thresholds detect absent or failed power supplies, and power supplies that are not in the correct slot for redundancy. | • Status Critical • Status Marginal • FICON Management Service |
BAD_TEMP — Temperature sensors outside range | Temperature thresholds, faulty temperature sensors. | ||
BAD_FAN — Absent or faulty fans | Fan thresholds, faulty fans. | ||
FLASH_USAGE2 — Flash usage | Flash thresholds. | ||
WWN_DOWN — WWN faulty or down | Faulty WWN card (applies to modular switches). | ||
DOWN_Core — Core blade monitoring | Faulty core blades. | ||
FAULTY_BLADE — Faulty blades | Faulty blades (applies to modular switches). | ||
HA_SYNC — HA monitoring | High availability (HA) state of the active CP is out of synchronization with the HA state of the standby CP. | ||
Local Switch | MARG_PORTS — Percentage of marginal ports | Physical port, E_Port, FOP_port (optical), and FCU_Port (copper) port thresholds. Whenever these thresholds are persistently high, the port is Marginal. | • Status Critical • Status Marginal • FICON Management Service |
FAULTY_PORTS — Percentage of faulty ports | Hardware-related port faults. | ||
MISSING_SFP — Percentage of missing SFP transceivers | Ports that are missing SFP transceiver. | ||
ERR_PORTS — Percentage of error ports | Ports with errors. |